Task: Allocation of functional safety requirements
The task of allocating functional safety requirements to subsystems on the basis of the functional concept and architectural assumptions, which provide the conceptual safety architecture.
Purpose

To show the traceability between safety goals, through the safety requirements to the specific subsystems.

The subsystems coming out of the conceptual safety architecture.

Relationships
RolesPrimary: Additional: Assisting:
InputsMandatory: Optional:
  • None
External:
  • None
Outputs
Main Description

The diagram below shows how the results of the Hazard analysis and risk assessment are passed down through the safety goals with ASIL levels to requirements and subsystems.

Hierarchy of Safety Goals and Functional Safety Requirements

             

This table/figure is taken from ISO 26262:2011-8.2 © ISO 2011 – All rights reserved. Reproduced with the permission of ANSI on behalf of ISO.

If several functional safety requirements are allocated to one subsystem then the functional safety requirement with the highest ASIL determines the ASIL of the subsystem, unless independence of freedom from interference cannot be argued in the development of the preliminary architecture.

If the item consists of more than one system, then the functional safety requirements for the individual systems and there interfaces shall be specified and allocated to the relevant systems, given the preliminary architecture.

ASIL decomposition can be applied to the functional safety requirements and preliminary architecture but it must be applied according to ISO 26262, vol 9 clause 6.

If the functional safety concept relies on elements of other technologies then a set of functional safety requirements shall be derived based upon the use of the technology and allocated to the appropriate parts of the architecture and the various interfaces with the technology. No ASIL shall be assigned to these elements as they are outside the scope of ISO 26262.

If the functional safety concept is to rely on external measures then a set of functional safety requirements implemented by these external measures and there interfaces shall be derived.

If the external measures are implemented in by one or more E/E systems then the related functional safety requirements shall be addressed using ISO 26262.

Copyright ISO 2011. All rights reserved. Reproduced with permission of ANSI.


Steps
Develop conceptual safety architecture

The conceptual safety architecture is developed so that the functional safety requirements can be allocated to subsystems.

For detailed guidance on this step refer to ISO 26262, Vol 3 clause 8.4.3.1

Optional:- ASIL Decomposition

The method of ASIL tailoring during the design process given in ISO 26262 is called "ASIL decomposition". During the allocation process, benefit can be obtained from architectural decisions and the existence of independent architectural elements. This offers the opportunity:

  • to implement safety requirements redundantly by these independent architectural elements; and
  • to assign a potentially lower ASIL to these redundant safety requirements.

If there is no independence between the elements, the ASIL of the safety goal is inherited by each requirement and element.

It is advised that users refer to ISO 26262, Vol 9, Clause 5 for detailed requirements and guidance on ASIL decomposition.

Allocate functional safety requirements

The task of allocating safety requirements to subsystems of the architecture.

The ASIL of the derived safety goal shall be passed to the subsystem.

For detailed guidance on this step refer to ISO 26262, Vol 3 clause 8.4.3.2


Properties
Predecessor
Multiple Occurrences
Event Driven
Ongoing
Optional
PlannedYes
Repeatable
Key Considerations

Practices applicable to help with requirements management

More Information